SISTEMAS DE ENSAIO AXIAL-TORSIONAL

Designed for combined axial and torsional loading, the BV series delivers comprehensive mechanical characterization of materials and components. Available in a wide range of load capacities, with torque up to 1000 Nm, our axial-torsion systems combine a compact and rigid design with the flexibility to integrate with our full range of actuators (both EA and UD).
Características

Max. Torque: 1000 Nm

Tipos de teste

Axial-Torsion
Estático
Dinâmico

Aplicativos

Materiais
Biomédico
Fios e parafusos

axial torsion testing machines
axial torsion testing machines

SISTEMAS DE ENSAIO AXIAL-TORSIONAL

Designed for combined axial and torsional loading, the BV series delivers comprehensive mechanical characterization of materials and components. Available in a wide range of load capacities, with torque up to 1000 Nm, our axial-torsion systems combine a compact and rigid design with the flexibility to integrate with our full range of actuators (both EA and UD).
Características

Max. Torque: 1000 Nm

Tipos de teste

Axial-Torsion
Estático
Dinâmico

Aplicativos

Materiais
Biomédico
Fios e parafusos

ENSAIO BIAXIAL

Axial e torcional

A série BV suporta perfis de teste tanto estáticos quanto dinâmicos, incluindo fadiga por torção, fadiga por carga combinada e análise de tensão multiaxial. Totalmente compatíveis com câmaras climáticas, extensômetros e uma ampla variedade de garras e acessórios, esses sistemas se adaptam aos requisitos de teste mais exigentes em ambientes de pesquisa e industriais.

  • Controle de dois ou mais eixos eletromecânicos sincronizados
  • Encoder rotativo absoluto
  • Aquisição de dados de alta resolução de 24 bits
  • Controle remoto
  • Estação de controle em localização separada e independente
  • Gerenciamento de testes simples e flexível por meio da interface gráfica do Test Center
  • Ampla variedade de garras, acessórios específicos para testes e células de carga
  • Integração com extensômetros e câmaras climáticas

Torque dinâmico máx. : 1000 Nm

Velocidade máx. : 350 rpm

Carga axial estática máx. admissível : 100 kN

Carga axial dinámica máx. admissível : 100 kN

  • Biomédico: Implantes, caracterização mecânica de ossos e tecidos moles, testes de instrumentos cirúrgicos
  • Setor automotivo: Ensaios de fadiga em eixos de transmissão, componentes de borracha, fixadores e peças de suspensão
  • Setor aeroespacial: Materiais compostos, componentes estruturais, análise de fadiga sob cargas combinadas
  • Ensaios de materiais: metais, plásticos, polímeros, ensaios de fadiga torcional e de ruptura

ESPECIFICAÇÕES TÉCNICAS

BV SERIESUNITSBV020BV035BV060BV080BV100BV170BV230BV1000
Continuos torqueNm15 25455580135160850
Dynamic torque (sinusoidal fatigue)Nm20 3560801001702301000
Test speedrpm350 35020015020020010085
Static axial load (max. admissible) *kN15 505050505050100
Dynamic axial load (max. admissible) *kN10.5 353535353535100
CoolingAirAirAirAirWater closed circuitWater closed circuitWater closed circuitWater closed circuit
Max. number of revolutions
±10000 *
Rotational absolute encoder
Integrated
* Higher values on request

RECURSOS

Sem manutenção

Alta confiabilidade

Alta eficiência

Controlador único

Instalação simples

NORMAS CERTIFICADAS

TESTAPPLICATIONSTANDARDDESCRIPTION
StaticPlasticsASTM D638Tensile properties of plastics
StaticPlasticsISO 527-1Plastics-Determination of tensile properties
StaticPlasticsISO 527-2Plastics-Determination of tensile properties
StaticMetalsASTM E21High temperature tensile testing of metallic materials
StaticMetalsASTM E290Material bending test for ductility
StaticMetalsASTM E517Plastic deformation ratio r for sheet metal
StaticMetalsASTM E646Tensile hardening exponents (n values) of sheet metal materials
StaticMetalsASTM E8MTensile testing of metallic materials
StaticMetalsASTM E9Compression testing of metallic materials at room temperature
StaticMetalsEN 10002-1:2001 (replaced by ISO EN 6892-1:2019)Tensile testing of metallic materials. Test method at room temperature
StaticMetalsISO 6892-1Metallic materials – Tensile testing Part 1: Test method at room temperature
StaticMetalsISO 7438Metallic materials. Proof of folding.
StaticMetalsISO 783Metallic materials – Tensile test of steel at elevated temperature
Static / FatigueBikeEN 15194Electrically assisted pedal cycles – EPAC Bicycles – test methods
Static / FatigueBikeISO 4210-3Safety requirements for bicycles – Part 3: Common test methods
Static / FatigueBikeISO 4210-4Safety requirements for bicycles – Part 4: Braking test methods
Static / FatigueBikeISO 4210-5Safety requirements for bicycles – Part 5: Steering test methods
Static / FatigueBikeISO 4210-6Safety requirements for bicycles – Part 6: Frame and fork test methods
Static / FatigueBikeISO 4210-7Safety requirements for bicycles – Part 7: Test methods for wheels and rims
Static / FatigueBikeISO 4210-8Safety requirements for bicycles – Part 8: Pedal and transmission system test methods
Static / FatigueBikeISO 4210-9Safety requirements for bicycles – Part 9: Test methods for saddles and seatposts
Static / FatigueBiomedicalASTM F1264Standard specifications and test methods for intramedullary fixation devices
Static / FatigueBiomedicalASTM F1717Standard test methods for spinal implant structures in a vertebrectomy model
Static / FatigueBiomedicalASTM F1798Standard test method for evaluating the static and fatigue properties of interconnecting mechanisms and subassemblies used in spinal arthrodesis implants
Static / FatigueBiomedicalASTM F1800Standard practice for cyclic fatigue testing of tibial plateau metal components of total knee joint replacements
Static / FatigueBiomedicalASTM F2068Standard specifications for femoral prostheses – metallic implants
Static / FatigueBiomedicalASTM F2077Test methods for intervertebral body fusion devices.
Static / FatigueBiomedicalASTM F2193Standard specifications and test methods for components used in surgical fixation of the spinal skeletal system
Static / FatigueBiomedicalASTM F2502Standard specifications and test methods for resorbable plates and screws for internal fixation implants
Static / FatigueBiomedicalASTM F2580Standard practice for evaluating the modular connection of a proximally fixed femoral hip prosthesis
Static / FatigueBiomedicalASTM F2706Standard test methods for occipito-cervical and occipito-cervical-thoracic spinal implant constructions in a vertebrectomy model
Static / FatigueBiomedicalASTM F382Standard specification and test method for metal bone plates
Static / FatigueBiomedicalASTM F384Standard specifications and test methods for angled metal devices for orthopedic fracture fixation
Static / FatigueBiomedicalASTM F543Standard specifications and test methods for metallic medical bone screws
Static / FatigueBiomedicalEN 843-1Mechanical properties of monolithic ceramics at room temperature – Determination of flexural strength
Static / FatigueBiomedicalISO 11405Dental structure adhesion testing
Static / FatigueBiomedicalISO 12189-8Mechanical testing of implantable spinal devices – Fatigue test method for spinal implant assemblies using anterior support
Static / FatigueBiomedicalISO 14801Dentistry – Implants – Dynamic load testing for endosseous dental implants
Static / FatigueBiomedicalISO 14879-1Total knee joint replacement Determination of strength properties of tibial knee trays
Static / FatigueBiomedicalISO 6872Dentistry – Ceramic Materials
Static / FatigueBiomedicalISO 7206Surgical implants – Partial and total hip joint replacements
Static / FatigueBiomedicalISO 9585Surgical implants – Determination of flexural strength and stiffness of bone plates
StaticRubberISO 2439Determination of hardness (indentation technique)
StaticRubberISO 3386Determination of compressive stress-strain characteristics
Navegue pelo nosso catálogo ou entre em contato conosco para encontrarmos juntos o produto certo para a sua empresa.