Serie UD | Units | UD01 | UD02 | UD04 | UD08 | UD012 | UD020 | UD025 | UD030 | UD040 | UD060 |
---|---|---|---|---|---|---|---|---|---|---|---|
Max. Dynamic Force | [kN][lbf] | 0.7 – 157.3 | 2.4 – 539.5 | 4.0 – 899.2 | 8.0 – 1798.5 | 12.0 – 2697.7 | 20.0 – 4496.2 | 25.0 – 5620.2 | 30.0 – 6744.3 | 40.0 – 8992.3 | 60.0 – 13488.5 |
Max. Static Force | [kN][lbf] | 0.5 – 112.4 | 1.5 – 3372.1 | 3.0 – 674.4 | 6.0 – 1349.9 | 9.0 – 2023.3 | 15.0 – 3372.1 | 18.0 – 4046.5 | 21.0 – 4720.9 | 30.0 – 6744.2 | 45.0 – 10116.4 |
Max. Test Speed | [m/s] [in/s] | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 | 2.0 – 78.7 |
Max. Test Frequency | [Hz] | >250* | >250* | >250* | >250* | >250* | >250* | >250* | >100* | >100* | >100* |
Standard Stroke | [mm] [in] | 80 – 3.1 | 100 – 3.9 | 70 – 2.7 | 70 – 2.7 | 70 – 2.7 | 80 – 2,7 | 70 – 2.7 | 60 – 2,3 | 80 – 2,7 | 80 – 2,7 |
Cooling | Air | Air | Air | Air | Air | Water closed circuit | Water closed circuit | Water closed circuit | Water closed circuit | Water closed circuit | |
Working Temperature | [C°] | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 |
Facility Requirement | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V |
Serie XUD | Units | XUD05 | XUD010 | XUD020 | XUD030 |
---|---|---|---|---|---|
Max. Peak Force | [kN] [lbf] | 5.5 – 1236.4 | 10.4 – 2338.0 | 20.5 – 4608.6 | 31.2 – 7014.0 |
Max. Dynamic Force | [kN] [lbf] | 1.5 – 337.2 | 2.7 – 606.9 | 5.4 – 1213.9 | 8.1 – 1820.9 |
Max. Static Force | [kN] [lbf] | 1.0 – 224.8 | 2.1 – 472.1 | 4.2 – 944.2 | 6.3 – 1416.3 |
Max. Test Speed | [m/s] [in/s] | 6.0 – 236.2 | 6.0 – 236.2 | 6.0 – 236.2 | 6.0 – 236.2 |
Max. Speed at Peak Force | [m/s] [in/s] | 4.0 – 157.4 | 4.0 – 157.4 | 4.0 – 157.4 | 4.0 – 157.4 |
Max. Test Frequency | (Hz) | >300* | >300* | >300* | >300* |
Standard Stroke | [mm] | 220 – 8.6 | 220 – 8.6 | 220 – 8.6 | 220 – 8.6 |
Cooling | Air | Air | Air | Air | |
Working Temperature | [C°] | 5-30 | 5-30 | 5-30 | 5-30 |
Facility Requirement | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V |
Serie HUD | Units | HUD010 HUD010L | HUD020 HUD020L | HUD030 HUD030L | HUD030-5/11 HUD030L-5/11 | HUD040-15 HUD040L-15 | HUD080-30 HUD080L-30 | HUD120-45 HUD120L-45 |
---|---|---|---|---|---|---|---|---|
Max. Peak Force | [kN] [lbf] | 11.0 – 2472.9 | 22.0 – 4945.8 | 33.0 – 7418.7 | 30.0 – 6744.2 | 40.0 – 8992.3 | 80.0 – 17984.7 | 120.0 – 26977.1 |
Max. Dynamic Force | [kN] [lbf] | 4.0 – 899.2 | 8.0 – 1798.5 | 12.0 – 2697.7 | 15.0 – 3372.1 | 20.0 – 4496.2 | 40.0 – 8992.4 | 60.0 – 13488.5 |
Max. Static Force | [kN] [lbf] | 3.0 – 674.4 | 6.0 – 1348.8 | 9.0 – 2023.3 | 11.0 – 2472.9 | 15.0 – 3372.1 | 30.0 – 6744.2 | 45.0 – 10116.4 |
Max. Test Speed | [m/s] [in/s] | 4.0/6.0 – 157.5/236.2 | 4.0/6.5 – 157.5/255.9 | 4.0/6.5 – 157.5/255.9 | 1.7/3.3 – 67.0/129.9 | 1.7/3.3 – 67.0/129.9 | 1.7/3.3 – 67.0/129.9 | 1.7/3.3 – 67.0/129.9 |
Max. Test Frequency | [Hz] | >125* | >125* | >125* | >100* | >100* | >100* | >100* |
Standard Stroke | [mm] [in] | 200 – 7.8 | 200 – 7.8 | 200 – 7.8 | 240 – 9.4 | 80 – 3.1 | 80/265 – 3.1/10.4 | 80/265 – 3.1/10.4 |
Cooling | Air | Air | Air | Air/Water closed circuit | Water closed circuit | Water closed circuit | Water closed circuit | |
Working Temperature | [C°] | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 | 5-30 |
Facility Requirement | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V | 3PH 400V |
Sistemi per test meccanici
Stiamo specializzati nello sviluppo di sistemi basati su motori lineari produciamo serie di macchine per applicazioni altamente dinamiche come gli ammortizzatori o i test di risonanza.
- Acquisizione dati ad alta risoluzione a 24 bit
- Può essere installato su qualsiasi tipo di struttura
- Fino a 8 assi controllati e sincronizzati
- Stazione di controllo in posizione separata e indipendente
- Gestione semplice e flessibile dei test tramite l’interfaccia grafica del Test Center
- Ampia varietà di griffe, accessori di prova dedicati e celle di carico
- Integrazione con estensimetri e camere climatiche
Stiamo specializzati nello sviluppo di sistemi basati su motori lineari produciamo serie di macchine per applicazioni altamente dinamiche come gli ammortizzatori o i test di risonanza.
- Acquisizione dati ad alta risoluzione a 24 bit
- Può essere installato su qualsiasi tipo di struttura
- Fino a 8 assi controllati e sincronizzati
- Stazione di controllo in posizione separata e indipendente
- Gestione semplice e flessibile dei test tramite l’interfaccia grafica del Test Center
- Ampia varietà di griffe, accessori di prova dedicati e celle di carico
- Integrazione con estensimetri e camere climatiche