AXIAL TORSION SYSTEMS
The best solution for tensile and torsion testing. BV systems are available in a wide range of loads, with torque capacities up to 230 Nm, the compact design requires minimal space and offers a high level of rigidity and alignment. The torsional motor is coupled to every linear actuator series we manufacture, from electromechanical actuators, EA series and all UD, HUD and XUD series based on linear motors.
Equipped with STEP Lab’s high-performance control electronics, the BV series provides accurate test and control data for testing products and specimens from every industry.
The industries where they mainly find application are biomedical, automotive and aerospace, but torsion testing are also common in the plastics industries, metals and fasteners.
- Control of two or more synchronised electromechanical axes
- Absolute rotary encoder
- High-resolution 24-bit data acquisition
- Remote control
- Control station in separate and independent position
- Simple and flexible test management via the graphical Test Center interface
- Wide range of grippers, dedicated test accessories and load cells
Integration with strain gauges and climatic chambers
FEATURES
Metric
BV SERIES | BV020 | BV035 | BV060 | BV080 | BV100 | BV110 | BV170 | BV230 |
---|---|---|---|---|---|---|---|---|
Continuos torque | 15 Nm | 25 Nm | 45 Nm | 55 Nm | 80 Nm | 100 Nm | 135 Nm | 160 Nm |
Dynamic torque (sinusoidal fatigue) | 20 Nm | 35 Nm | 60 Nm | 80 Nm | 100 Nm | 110 Nm | 170 Nm | 230 Nm |
Test speed | 350 rpm | 350 rpm | 200 rpm | 150 rpm | 200 rpm | 300 rpm | 200 rpm | 100 rpm |
Static axial load (max. admissible) * | 15 kN | 50 kN | 50 kN | 50 kN | 50 kN | 50 kN | 50 kN | 50 kN |
Dynamic axial load (max. admissible) * | 10.5 kN | 35 kN | 35 kN | 35 kN | 35 kN | 35 kN | 35 kN | 35 kN |
Cooling | Air | Air | Air | Air | Water closed circuit | Air | Water closed circuit | Water closed circuit |
Max. number of revolutions | ||||||||
Rotational absolute encoder |
Imperial
Certified Standards
Plastics
PROOF | MATERIAL | NORMA | DESCRIPTION |
Static tests | Plastic | ASTM D638 | Tensile properties of plastics |
Static tests | Plastic | ISO 527-1 ISO 527-2 |
Plastics-Determination of Tensile Properties |
Metal
PROOF | MATERIAL | NORMA | DESCRIPTION |
Static tests | Metal | ASTM E21 | High-temperature tensile testing of metallic materials |
Static tests | Metal | ASTM E290 | Material bending test for ductility |
Static tests | Metal | ASTM E517 | Plastic deformation ratio r for sheet metal |
Static tests | Metal | ASTM E646 | Tensile hardening exponents (n-values) of sheet metal materials |
Static tests | Metal | ASTM E8M | Tensile testing of metallic materials |
Static tests | Metal | ASTM E9 | Compression testing of metallic materials at room temperature |
Static tests | Metal | EN 10002-1:2001 (replaced by ISO EN 6892-1:2019) | Tensile testing of metallic materials. Test method at room temperature |
Static tests | Metal | ISO 6892-1 | Metallic materials – Tensile testing Part 1: Test method at room temperature |
Static tests | Metal | ISO 7438 | Metallic materials. Proof of folding. |
Static tests | Metal | ISO 783 | Metallic materials – Tensile test of steel at high temperature |
Bicycles
PROOF | MATERIAL | NORMA | DESCRIPTION |
Static / Fatigue | Bikes | EN 15194 | Electrically assisted pedal cycles – EPAC Bicycles – test methods |
Static / Fatigue | Bikes | ISO 4210-3 | Bicycle safety requirements – Part 3: Common test methods |
Static / Fatigue | Bikes | ISO 4210-4 | Safety requirements for bicycles – Part 4: Braking test methods |
Static / Fatigue | Bikes | ISO 4210-5 | Bicycle safety requirements – Part 5: Steering test methods |
Static / Fatigue | Bikes | ISO 4210-6 | Safety requirements for bicycles – Part 6: Test methods for frame and fork |
Static / Fatigue | Bikes | ISO 4210-7 | Bicycle safety requirements – Part 7: Test methods for wheels and rims |
Static / Fatigue | Bikes | ISO 4210-8 | Safety requirements for bicycles – Part 8: Pedal and drive system test methods |
Static / Fatigue | Bikes | ISO 4210-9 | Bicycle safety requirements – Part 9: Test methods for saddles and seatposts |
Biomedical
PROOF | MATERIAL | NORMA | DESCRIPTION |
Static / Fatigue | Biomedical | ASTM F1264 | Standard Specifications and Test Methods for Intramedullary Fixation Devices |
Static / Fatigue | Biomedical | ASTM F1717 | Standard test methods for spinal implant structures in a vertebrectomy model |
Static / Fatigue | Biomedical | ASTM F1798 | Standard test method for the evaluation of static and fatigue properties of interconnection mechanisms and subassemblies used in spinal arthrodesis implants |
Static / Fatigue | Biomedical | ASTM F1800 | Standard Practice for Cyclic Fatigue Testing of Metal Components of the Tibial Plateau of Total Knee Joint Prostheses |
Static / Fatigue | Biomedical | ASTM F2068 | Standard specifications for femoral prostheses – metal implants |
Static / Fatigue | Biomedical | ASTM F2077 | Test methods for intervertebral body fusion devices |
Static / Fatigue | Biomedical | ASTM F2193 | Standard specifications and test methods for components used in surgical fixation of the spinal skeletal system |
Static / Fatigue | Biomedical | ASTM F2502 | Standard specifications and test methods for resorbable plates and screws for internal fixation implants |
Static / Fatigue | Biomedical | ASTM F2580 | Standard practice for evaluating the modular connection of a proximally fixed femoral hip prosthesis |
Static / Fatigue | Biomedical | ASTM F2706 | Standard test methods for occipito-cervical and occipito-cervical-thoracic spinal implant constructions in a vertebrectomy model |
Static / Fatigue | Biomedical | ASTM F382 | Standard Specifications and Test Method for Metal Bone Plates |
Static / Fatigue | Biomedical | ASTM F384 | Standard specifications and test methods for angled metal devices for orthopaedic fracture fixation |
Static / Fatigue | Biomedical | ASTM F543 | Standard Specifications and Test Methods for Metal Medical Bone Screws |
Static / Fatigue | Biomedical | EN 843-1 | Mechanical properties of monolithic ceramics at room temperature – Determination of flexural strength |
Static / Fatigue | Biomedical | ISO 11405 | Tooth structure adhesion test |
Static / Fatigue | Biomedical | ISO 12189-8 | Mechanical testing of implantable spinal devices – Fatigue test method for spinal implant assemblies using anterior support |
Static / Fatigue | Biomedical | ISO 14801 | Dentistry – Implants – Dynamic load test for endosseous dental implants |
Static / Fatigue | Biomedical | ISO 14879-1 | Total knee joint replacement Determining the strength properties of tibial knee trays |
Static / Fatigue | Biomedical | ISO 6872 | Dentistry – Ceramic materials |
Static / Fatigue | Biomedical | ISO 7206 | Surgical implants – Partial and total hip joint replacements |
Static / Fatigue | Biomedical | ISO 9585 | Surgical implants – Determination of flexural strength and stiffness of bone plates |
Rubber
PROOF | MATERIAL | NORMA | DESCRIPTION |
Static tests | Rubber | ISO 2439 | Determination of hardness (indentation technique) |
Static tests | Rubber | ISO 3386 | Determination of stress-strain characteristics in compression |